Technical Specifications
CategoryHeat Pumps & Fan Coils
BrandLG
Outdoor Temperature Operating Range (Heating)-28°C to 35°C
Seasonal Heating Efficiency ηs (35°C water)205 %
Heat Output at -7°C (kW)9.00 kW (A-7/W35) / 8.00 kW (A-7/W55)
Heating Energy Class (35°C)A+++
Supply Water Temperature Range (Heating)15°C to 75°C (according to the indoor unit table)
RefrigerantR290
Indoor UnitCombi Unit
Supply Water Temperature Range (Cooling)5°C to 27°C
Electrical Characteristics1~/50Hz/220-240V
Cooling EER4.20 (A35/W18) / 2.60 (A35/W7)
Heating Energy Class (55°C)A+++
Outdoor Temperature Operating Range (Cooling)5°C to 48°C
Maximum Supply Water Temperature (°C)75 °C (according to the indoor unit table)
Heating SCOP (55°C water)3.86
Outdoor Unit Sound Pressure Level - Low Noise (dBA)26 (at 5 m)
PhaseSingle-phase
Outdoor Unit Sound Pressure Level (dBA)28 (at 5 m)
Heat Output (kW)9.00 kW (A7/W35) / 5.50 kW (A7/W55) / 8.00 kW (A2/W35)
Standby Consumption (W)10
Seasonal Heating Efficiency ηs (55°C water)151 %
Outdoor Unit Weight (kg)130.0
Heating COP at -7°C2.70 (A-7/W35) / 2.20 (A-7/W55)
Cooling Output (kW)5.50 kW (A35/W18) / 5.50 kW (A35/W7)
Recommended Circuit Breaker (A)20
Measurement ConditionsA: outdoor air temperature, W: leaving water temperature (LWT)
Outdoor UnitHM091HF UB40
Capacity (kW)9 kW
Water Pipe ConnectionsMale PT 1" (ISO 7-1)
Refrigerant - DetailsR290, GWP 3, 0.9 kg (0.0027 t CO2eq)
Outdoor Unit Sound Power Level - Low Noise (dB)48
Outdoor Unit Sound Power Level LW(A) (dB)50
Outdoor Unit Dimensions (HxWxD mm)1019 x 1320 x 520
Heating COP4.70 (A7/W35) / 3.30 (A7/W55) / 3.70 (A2/W35)
Heating SCOP (35°C water)5.20