← LG
LG THERMA V R290 Monobloc
LG

LG THERMA V R290 Monobloc

LG THERMA V (R290 Monobloc) air-to-water heat pump, 7kW, single-phase. Refrigerant R290.

Choose Capacity

Download Catalogue (PDF)
Technical Specifications
CategoryHeat Pumps & Fan Coils
BrandLG
Heating COP at -7°C2.80 (A-7/W35) / 2.40 (A-7/W55)
Supply Water Temperature Range (Heating)15°C to 75°C (according to the indoor unit table)
Maximum Supply Water Temperature (°C)75 °C (according to the indoor unit table)
Heating Energy Class (35°C)A+++
Outdoor Unit Sound Power Level - Low Noise (dB)48
Outdoor Unit Sound Power Level LW(A) (dB)49
Supply Water Temperature Range (Cooling)5°C to 27°C
Outdoor Temperature Operating Range (Heating)-28°C to 35°C
Outdoor UnitHM071HF UB40
Standby Consumption (W)10
Heat Output at -7°C (kW)7.00 kW (A-7/W35) / 7.00 kW (A-7/W55)
Outdoor Unit Weight (kg)130.0
Seasonal Heating Efficiency ηs (35°C water)207 %
Water Pipe ConnectionsMale PT 1" (ISO 7-1)
Heating Energy Class (55°C)A+++
PhaseSingle-phase
Heating SCOP (55°C water)3.86
Seasonal Heating Efficiency ηs (55°C water)151 %
RefrigerantR290
Outdoor Temperature Operating Range (Cooling)5°C to 48°C
Heating SCOP (35°C water)5.24
Heating COP5.00 (A7/W35) / 3.35 (A7/W55) / 3.80 (A2/W35)
Outdoor Unit Sound Pressure Level (dBA)27 (at 5 m)
Measurement ConditionsA: outdoor air temperature, W: leaving water temperature (LWT)
Cooling EER4.40 (A35/W18) / 2.80 (A35/W7)
Heat Output (kW)7.00 kW (A7/W35) / 4.50 kW (A7/W55) / 7.00 kW (A2/W35)
Capacity (kW)7 kW
Refrigerant - DetailsR290, GWP 3, 0.9 kg (0.0027 t CO2eq)
Recommended Circuit Breaker (A)20
Outdoor Unit Sound Pressure Level - Low Noise (dBA)26 (at 5 m)
Cooling Output (kW)5.00 kW (A35/W18) / 5.00 kW (A35/W7)
Electrical Characteristics1~/50Hz/220-240V
Indoor UnitCombi Unit
Outdoor Unit Dimensions (HxWxD mm)1019 x 1320 x 520