← LG THERMA V Monobloc
Technical Specifications
CategoryHeat Pumps & Fan Coils
BrandLG
Heating Circuit Expansion Vessel (l)8
Water Pipe ConnectionsMale PT 1" (ISO 7-1), inlet/outlet
Outdoor Temperature Operating Range (Heating)-25°C to 35°C
Indoor UnitMonobloc (all-in-one)
Cooling Output (kW)7.00 kW (A35/W18) / 7.00 kW (A35/W7)
Measurement ConditionsA: outdoor air temperature, W: leaving water temperature (LWT)
Electrical Characteristics1~/50Hz/220-240V
PhaseSingle-phase
Outdoor Unit Sound Pressure Level (dBA)35 (at 5 m)
Seasonal Heating Efficiency ηs (55°C water)125 %
Heat Output (kW)7.00 kW (A7/W35) / 5.75 kW (A7/W55) / 6.00 kW (A2/W35)
Seasonal Heating Efficiency ηs (35°C water)176 %
Heating SCOP (55°C water)3.20
Supply Water Temperature Range (Cooling)5°C to 27°C (16°C to 27°C when no fan coil is used)
Heating SCOP (35°C water)4.48
Recommended Circuit Breaker (A)20
Standby Consumption (W)10
Maximum Supply Water Temperature (°C)65 °C
Heating Energy Class (55°C)A++
Heating COP4.70 (A7/W35) / 2.70 (A7/W55) / 3.55 (A2/W35)
Supply Water Temperature Range (Heating)15°C to 65°C
Outdoor Unit Sound Power Level - Low Noise (dB)55
Outdoor Unit Sound Power Level LW(A) (dB)57
Water Temperature Range (Domestic Hot Water)15°C to 80°C (above 55°C only with booster heater operation)
Outdoor Temperature Operating Range (Cooling)5°C to 48°C
Capacity (kW)7 kW
Outdoor Unit Dimensions (HxWxD mm)853 x 1242 x 391
Refrigerant - DetailsR32, GWP 675, 1.4 kg
Heating Energy Class (35°C)A+++
RefrigerantR32
Outdoor Unit Sound Pressure Level - Low Noise (dBA)33 (at 5 m)
Outdoor UnitHM071MRS UA40
Outdoor Unit Weight (kg)94
Cooling EER4.65 (A35/W18) / 3.20 (A35/W7)