LG
Air Conditioner STANDARD UM36F.N20 (IN) – UUD3.U30 (OUT) – PREMTB001 (CONTROL)
Operating Voltage: 240 V / 50 Hz Indoor/Outdoor Unit Airflow (m³/min): 32/55 Outdoor Unit Dimensions (mm), (L x H x W): 950 x 1380 x 330 Outdoor Unit Weight (kg): 85 Maximum Pipe Length (m): 85 Refrigerant Type / Charge (kg): R32/3
Choose Capacity
Download Technical Datasheet (PDF)Technical Specifications
CategoryAir Conditioning
BrandLG
Cooling Energy ClassA+
Indoor Noise Level (High/Medium/Low)36/34/33 dB(A)
Operating Current (Cooling)4,0 A
SCOP3,9
Indoor/Outdoor Unit Airflow (m^3/min)32/55
Heating Energy ClassA
Outdoor Temperature Operating Range (Cooling)-20°C to 52°C
Indoor Unit Sound Power Level (Cooling)60 dB(A)
Pipe Connection TypeFlared
Liquid Pipe DiameterØ9,52 (3/8")
Compressor TypeInverter Scroll
Indoor Unit Dimensions (WxHxD)1.250 x 270 x 700 mm
Outdoor Unit Fan (m³/min × number)55 x 2
Outdoor Unit Sound Pressure Level (Heating)50 dB(A)
Refrigerant - DetailsR32, GWP 675, 3,0 kg (2,025 t CO2eq)
Refrigerant Type / Charge (kg)R32/3
Gas Pipe DiameterØ15,88 (5/8")
Power Input (Cooling)2,50 kW (0,50-3,80)
Annual Energy Consumption (Cooling)573 kWh
Outdoor Unit Power Cable5C x 2,5 mm²
Maximum Height Difference Between Units (m)30
Maximum Pipe Length (m)85
Indoor Unit Weight38,5 kg
Pumped Drain Diameter (Ø ext./int.)Ø32,0 / 26,0 mm
Minimum Outdoor Unit Fuse Rating (A)20
COP3,90
Outdoor Temperature Operating Range (Heating)-25°C to 18°C
Outdoor Unit Sound Power Level (Cooling)66 dB(A)
Cooling Output (Cooling)9.5 kW (estimate based on the equivalent UM36FH class)
Indoor Unit Power Input (High/Medium/Low)183/134/101 W
Pdesign (Heating)9,5 kW (-10°C)
Additional Refrigerant (g/m)40 g/m (beyond 7.5 m)
Operating Voltage380-415 V / 50 Hz (3 phases)
Outdoor Unit Dimensions (mm), (L x H x W)950 x 1380 x 330
Pdesign (Cooling)9,5 kW (35°C)
Gravity Drain Diameter (Ø ext./int.)Ø25,4 / 19,4 mm
Power Input (Heating)2,77 kW (0,60-3,77)
SEER5,8
Outdoor Unit Weight (kg)85
Operating Current (Heating)4,5 A
Indoor Unit Power Supply1~ / 220-240 V / 50 Hz
Dehumidification Rate (l/h)2,9
Annual Energy Consumption (Heating)3.410 kWh
Heat Output (Heating)10.8 kW (estimate based on the equivalent UM36FH class)
Static PressureMedium
EER3,80
Indoor Unit Airflow (High/Medium/Low)32/28/24 m³/min
Pipe Length Minimum / Maximum (m)5 / 85
Outdoor Unit Sound Pressure Level (Cooling)50 dB(A)