Olympus
200‐1‐S230
TANK Dimensions (mm): 530 x 1215 Capacity (l) : 200 COLLECTOR Dimensions (mm): 1960 x 960 x 81 Number of Collectors: 1 Collector Area (m²): 2.28 Maximum Operating Pressure (bar) : 22.5
Download Catalogue (PDF)Technical Specifications
CategorySolar Water Heaters - Boilers
BrandOlympus
Emissivity (ε)5% (±0,02)
Maximum Collector Circuit Operating Pressure (bar)15
Water Temperature Retentionup to 48 hours
Collector Cover3.2 mm low-iron prismatic solar glass, 90.5% transmittance
Anodic ProtectionMagnesium rod
Absorptance (α)95% (±0,02)
Number of Collectors1
Collector SealingAcrylic foam, structural silicone
Collector Insulation40 mm stone wool (50 kg/m³) at the back and 20 mm glass wool (30 kg/m³) at the sides
Collector FrameAluminium profile, without screws or nails
Heat ExchangerInternal heat exchanger of EN 10219 steel, 3.0 mm thick
Tank MaterialUSD 37.2 steel with double enamel (glass) coating, fired at 860°C
Maximum Tank Operating Pressure (bar)10
Maximum Collector Operating Temperature (°C)150
Collector Weight (kg)35,5
Collector Area (m²)2,28
Tank Capacity200 Lt
Empty Tank Weight (kg)61
Backup Electric HeaterYes
Collector Efficiency (η0)0,763
Absorber Material0.50 mm selective blue aluminium, laser-welded to copper tubes
Collector Dimensions (mm)1960 x 960 x 81
Tank Outer CoverGalvanised sheet steel with electrostatic paint, RAL 9006
Collector Circuit Test Pressure (bar)22,5
System TypeClosed-circuit thermosiphon solar system
Maximum Operating Pressure (bar)22,5
CertificationSolar Keymark, EN 12976-1/2, EN 12975-2 (collector)
Tank Dimensions (mm)530 x 1215
Maximum Collector Circuit Temperature (°C)150
Tank InsulationCFC-free polyurethane 40-50 mm (40 kg/m³)