← LG
STANDARD Duct CL Air Conditioner
LG

STANDARD Duct CL Air Conditioner

Operating Voltage: 220-240 V / 50 Hz Indoor/Outdoor Unit Airflow (m³/min): 11.5/28 Outdoor Unit Dimensions (mm), (L x H x W): 770 x 545 x 288 Outdoor Unit Weight (kg): 33.3 Maximum Pipe Length (m): 30 Refrigerant Type / Charge (kg): R32/1

Choose Capacity

Download Technical Datasheet (PDF)
Technical Specifications
CategoryAir Conditioning
BrandLG
Indoor Unit Dimensions (WxHxD)900 x 190 x 460 mm
Heat Output (Heating)3,2 kW (1,8-4,0)
Indoor Unit Airflow (High/Medium/Low)11,5/9,5/8 m³/min
Indoor Unit Sound Power Level (Cooling)55 dB(A)
Outdoor Unit Sound Pressure Level (Cooling)49 dB(A)
Operating Current (Cooling)3,0 A
Outdoor Temperature Operating Range (Cooling)-15°C to 50°C
Operating Voltage220-240 V/ 50 Hz
Pdesign (Cooling)2,5 kW (35°C)
Cooling Energy ClassA++
Pdesign (Heating)2,9 kW (-10°C)
Pipe Length Minimum / Maximum (m)5 / 30
Indoor Unit Power Supply1~ / 220-240 V / 50 Hz
Refrigerant Type / Charge (kg)R32/1
Outdoor Unit Weight (kg)33,3
Outdoor Unit Sound Pressure Level (Heating)52 dB(A)
Maximum Pipe Length (m)30
Outdoor Temperature Operating Range (Heating)-20°C to 18°C
Liquid Pipe DiameterØ6,35 (1/4")
Indoor Noise Level (High/Medium/Low)35/30/27 dB(A)
Annual Energy Consumption (Heating)1.015 kWh
Static PressureLow
SCOP4,0
Compressor TypeTwin Rotary
Outdoor Unit Power Cable3C x 1,5 mm²
Outdoor Unit Sound Power Level (Cooling)65 dB(A)
Outdoor Unit Dimensions (mm), (L x H x W)770 x 545 x 288
Heating Energy ClassA+
Indoor Unit Weight18,0 kg
Annual Energy Consumption (Cooling)143 kWh
Pipe Connection TypeFlared
Operating Current (Heating)3,3 A
Maximum Height Difference Between Units (m)30
Cooling Output (Cooling)2,5 kW (1,5-3,2)
Minimum Outdoor Unit Fuse Rating (A)15
Power Input (Cooling)0,67 kW (0,30-0,93)
Drain Diameter (Ø ext./int.)Ø32,0 / 26,0 mm
Dehumidification Rate (l/h)0,2
COP4,30
Refrigerant - DetailsR32, GWP 675, 1,0 kg (0,675 t CO2eq)
Power Input (Heating)0,75 kW (0,38-1,63)
Additional Refrigerant (g/m)20 g/m (beyond 7.5 m)
Indoor Unit Power Input (High/Medium/Low)21/15/13 W
EER3,80
Gas Pipe DiameterØ9,52 (3/8")
Indoor/Outdoor Unit Airflow (m^3/min)11,5/28
Outdoor Unit Fan (m³/min × number)28 x 1
SEER6,1